Service and repair for your
Hach 2100Q Portable Turbidmeter Kit
Most common repairs + troubleshooting for the Hach 2100Q Portable Turbidmeter Kit at Acme:
- Low Battery Warning: Indicative of batteries needing replacement or recharge, especially critical during field measurements.
- Lid Open Error: Occurs when the lid is not properly closed during measurements, affecting the accuracy and repeatability of readings.
- ADC Failure or Detector Signal Too Low: Suggests a hardware malfunction or obstruction in the light path, potentially due to dirty or incorrectly placed sample cells.
- Overrange/Underrange Error: Reflects measurements outside the calibrated range, possibly due to improper calibration or sample preparation.
- Please Check the Lamp Error: Indicates issues with the lamp, such as failure or insufficient light reaching the detectors, requiring lamp replacement for the 2100Q model.
- Temperature Too High Warning: Alerts when the device operates beyond its temperature limits, necessitating a cool-down period.
- Rapidly Settling Turbidity (RST) Mode Issues: Highlights problems with the RST reading mode, such as samples settling too slowly or the confidence level being below 95%.
- Rapidly Settling Turbidity (RST) Mode Issues: Highlights problems with the RST reading mode, such as samples settling too slowly or the confidence level being below 95%.
- Standard Value Out of Range: Occurs during calibration if the wrong standard is used or if the sample does not match the expected turbidity range.
- Sample Cell and Cap Maintenance: Relates to issues from not using clean, scratch-free sample cells or properly applying silicone oil, impacting measurement accuracy.
est repair cost: $45 per hour
321 parts + components available at: ACME REVIVAL DENVER
Exterior
Internal (Mechanical)
Circuitry
Plastics
$45 Per Hour
Acme bills $45 per hour for the Hach 2100Q Portable Turbidmeter Kit with a no-obligation diagnostic evaluation upon arrival. Don’t like the quote? We’ll send it back.
Free Return Shipping
We’ll send back your device for free regardless of its size or weight, anywhere in the world.
30-Day Guarantee
Acme guarantees service for no fewer than 30 days from return service delivery. Some device may qualify for extended warranty options.
Nearest Facility to You
Acme Revival Denver
2016 W Hamilton Place
Sheridan, CO 80110
Capacity: up to 150 tickets per week
Specialities: Medical, Industrial, Electro-Mechanical
Receiving Hours:
- Monday 9:00 a.m. - 5:00 p.m.
- Tuesday 9:00 a.m. - 5:00 p.m.
- Wednesday 9:00 a.m. - 5:00 p.m.
- Thursday 9:00 a.m. - 5:00 p.m.
- Friday 9:00 a.m. - 5:00 p.m.
- Saturday Closed
- Sunday Closed